| Category | Message | Cause | Remedy | SELF-CORRECTING? | ATTENDANT INTERVENTION? | DATA LOSSES OR CHANGES DUE TO ERROR RESET | SAS Exception | Lockup | Tower Light |
|---|---|---|---|---|---|---|---|---|---|
| TICKET PRINTER ERRORS | TICKET PRINTER OPEN | The printer cover is open. | Close the printer cover. | NO | YES | NONE | ? | Flash | |
| TICKET PRINTER ERRORS | TICKET PRINTER PAPER EMPTY | The printer has run out of paper. | Refill with paper. | NO | YES | NONE | ? | Flash | |
| TICKET PRINTER ERRORS | TICKET PRINTER PAPER LOW | Remaining paper level is low. | Refill with paper. | NO | YES | NONE | ? | No | Not flash |
| TICKET PRINTER ERRORS | TICKET PRINTER PAPER JAM | Paper jammed during printing. | Clear any Paper jam. | NO | YES | NONE | ? | Flash | |
| TICKET PRINTER ERRORS | TICKET PRINTER DISCONNECTED | It is not possible to communicate with the Ticket Printer. | Reconnect or replace the cable. | NO | YES | NONE | ? | Flash | |
| TICKET PRINTER ERRORS | TICKET PRINT TIMED OUT | Ticket printing was not completed within the required time. | RESET key. | ? | YES | NONE | ? | Flash | |
| SYSTEM ERRORS | COMMUNICATION #1 ERROR (BODY PCB) | Displayed when the BODY PCB is incorrect. | Power off Reconnect Body PCB Power on | NO | YES | NONE | 20 | Flash | |
| SYSTEM ERRORS | COMMUNICATION #2 ERROR (DOOR PCB) | No communication with the target PCB. | Replacing target PCB. | NO | YES | NONE | ? | Flash | |
| SYSTEM ERRORS | COMMUNICATION #3 ERROR (XCOM PCB) | No communication with the target PCB. | Replacing target PCB. | NO | YES | NONE | N/A | Flash | |
| SYSTEM ERRORS | LOW BACKUP BATTERY (ZIO BOARD) | The remaining battery of the target PCB is lower than a specified level. | Replace the battery. | NO | YES | NONE | ? | Flash | |
| SYSTEM ERRORS | LOW BACKUP BATTERY (BODY PCB) | Displayed when the battery for the BODY PCB is low. | Power off Replace a battery Power on | NO | YES | NONE | Flash | ||
| SYSTEM ERRORS | LOW BACKUP BATTERY (DOOR PCB) | The remaining battery of the target PCB is lower than a specified level. | Replace the battery. | NO | YES | NONE | ? | Flash | |
| SYSTEM ERRORS | LOW BACKUP BATTERY (XCOM PCB) | The remaining battery of the target PCB is lower than a specified level. | Replace the battery. | NO | YES | NONE | ? | Flash | |
| SYSTEM ERRORS | POWER RESET | EGM‚ªƒŠƒu[ƒg‚µ‚½H | AUTOMATIC | YES | NO | NONE | ? | No | Not flash |
| SYSTEM ERRORS | CABINET FAN (UPPER) ABNORMAL | The Fan does not rotate properly. | Replace the fan | NO | YES | NONE | ? | Flash | |
| SYSTEM ERRORS | CABINET FAN (LOWER) ABNORMAL | The Fan does not rotate properly. | Replace the fan | NO | YES | NONE | ? | Flash | |
| SYSTEM ERRORS | POWER SUPPLY FAN ABNORMAL | The Fan does not rotate properly. | Replace the fan | NO | YES | NONE | ? | Flash | |
| SYSTEM ERRORS | 1ST MONITOR COMMUNICATION OFFLINE ERROR | Flash | |||||||
| SYSTEM ERRORS | 2ND MONITOR COMMUNICATION OFFLINE ERROR | Flash | |||||||
| SYSTEM ERRORS | 3RD MONITOR COMMUNICATION OFFLINE ERROR | Flash | |||||||
| SYSTEM ERRORS | COMMUNICATION #5 ERROR (NOKI PCB) | Displayed when the NOKI PCB is incorrect. | Power off Reconnect Noki PCB Power on | NO | YES | NONE | Flash | ||
| SYSTEM ERRORS | COMMUNICATION #6 ERROR (SIGA PCB) | No communication with the target PCB. | Replacing target PCB. | NO | YES | NONE | ? | Flash | |
| SYSTEM ERRORS | COMMUNICATION #7 ERROR (SIGB PCB) | No communication with the target PCB. | Replacing target PCB. | NO | YES | NONE | ? | Flash | |
| SYSTEM ERRORS | COMMUNICATION #8 ERROR (SIGC PCB) | No communication with the target PCB. | Replacing target PCB. | NO | YES | NONE | ? | Flash | |
| SYSTEM ERRORS | COMMUNICATION #9 ERROR (SIGD PCB) | No communication with the target PCB. | Replacing target PCB. | NO | YES | NONE | ? | Flash | |
| SYSTEM ERRORS | POWER SUPPLY BOX ERROR | An anomaly was detected by the temperature sensor of the Power Supply Box. | The power supply requires replacement. | NO | YES | NONE | ? | Flash | |
| SYSTEM ERRORS | LOW BACKUP BATTERY (NOKI PCB) | Displayed when the battery for the NOKI PCB is low. | Power off Replace a battery Power on | NO | YES | NONE | Flash | ||
| SYSTEM ERRORS | LOW BACKUP BATTERY (SIGA PCB) | The remaining battery of the target PCB is lower than a specified level. | Replace the battery. | NO | YES | NONE | ? | Flash | |
| SYSTEM ERRORS | LOW BACKUP BATTERY (SIGB PCB) | The remaining battery of the target PCB is lower than a specified level. | Replace the battery. | NO | YES | NONE | ? | Flash | |
| SYSTEM ERRORS | LOW BACKUP BATTERY (SIGC PCB) | The remaining battery of the target PCB is lower than a specified level. | Replace the battery. | NO | YES | NONE | ? | Flash | |
| SYSTEM ERRORS | LOW BACKUP BATTERY (SIGD PCB) | The remaining battery of the target PCB is lower than a specified level. | Replace the battery. | NO | YES | NONE | ? | Flash | |
| SYSTEM ERRORS | PSU BOX FAN ABNORMAL | The Fan does not rotate properly. | Replace the fan | NO | YES | NONE | ? | Flash | |
| SYSTEM ERRORS | PSU BOX THERMAL ERROR | An anomaly was detected by the temperature sensor of the PSU Box. | The power supply requires replacement. | NO | YES | NONE | ? | Flash | |
| SYSTEM ERRORS | MINI PC / PIT BOSS PC DISCONNECTED | Flash | |||||||
| SHOWTIME FRENZY | SERVER NETWORK ERROR | Communication between the Station and the Center Unit is disconnected. | RESET key. | NO | YES | NONE | ? | Flash | |
| SHOWTIME FRENZY | NOW CONNECTING... | Displayed while the main unit is connecting to the network. | AUTOMATIC | NO | YES | NONE | Flash | ||
| SHOWTIME FRENZY | CLIENT ID ERROR | It took too much time to restore the connection to the Casino Host. | Reboot the machine | YES | YES | NONE | ? | Flash | |
| SHOWTIME FRENZY | WAITING TO RECIEVE CONFIGURATIONS | Flash | |||||||
| SHOWTIME FRENZY | CONFIGURATIONS IS CHANGED. PLEASE POWER OFF-ON. | Flash | |||||||
| SHOWTIME FRENZY | BASE PROTOCOL VERSION IS UNMATHED | Flash | |||||||
| SHOWTIME FRENZY | GAME PROTOCOL VERSION IS UNMATHED | Flash | |||||||
| SHOWTIME FRENZY | GAME FAILURE ERROR | Game play could not be executed because an error occurred. | Clear all errors. | YES | YES | NONE | ? | Flash | |
| SHOWTIME FRENZY | LIVE CAMERA DISCONNECTED | The Live Camera is not connected. | Check connection | YES | YES | NONE | ? | Flash | |
| SHOWTIME FRENZY | SELF CHI SQUARE TEST FAILURE | Flash | |||||||
| SHOWTIME FRENZY | WHEEL MAINTENANCE REQUIRED CALL ARUZE SERVICE | Flash | |||||||
| SHOWTIME FRENZY | WHEEL MAINTENANCE REQUIRED | Flash | |||||||
| SHOWTIME FRENZY | WARNING!! CONFIGURE MAIN UNIT ID | Flash | |||||||
| SHOWTIME FRENZY | GAME INIT ERROR | Flash | |||||||
| SHOWTIME FRENZY | BALL FALL ERROR | Flash | |||||||
| SHOWTIME FRENZY | COMPRESSOR ERROR | Flash | |||||||
| SHOWTIME FRENZY | BALL COUNT ERROR | Flash | |||||||
| SHOWTIME FRENZY | BALL START ERROR | Flash | |||||||
| SHOWTIME FRENZY | POSITION SENSOR ERROR(REF0130) | Flash | |||||||
| SHOWTIME FRENZY | POSITION SENSOR ERROR(REF0430) | Flash | |||||||
| SHOWTIME FRENZY | POSITION SENSOR ERROR(REF0730) | Flash | |||||||
| SHOWTIME FRENZY | POSITION SENSOR ERROR(REF1030) | Flash | |||||||
| SHOWTIME FRENZY | ZERO SENSOR ERROR | Flash | |||||||
| SHOWTIME FRENZY | ZERO SENSOR DETECT ERROR | Flash | |||||||
| SHOWTIME FRENZY | AROUND SENSOR ERROR | Flash | |||||||
| SHOWTIME FRENZY | ENCODER COUNT ERROR | Flash | |||||||
| SHOWTIME FRENZY | MOTOR ERROR | Flash | |||||||
| SHOWTIME FRENZY | POCKET SHUFFLE ERROR | Flash | |||||||
| SHOWTIME FRENZY | WHEEL ORIGIN DETECT ERROR | Flash | |||||||
| SHOWTIME FRENZY | WHEEL DIRECTION ERROR | Flash | |||||||
| SHOWTIME FRENZY | WHEEL TYPE MISMATCH | Flash | |||||||
| SHOWTIME FRENZY | CONSECUTIVE SAME RESULTS OF A WHEEL | Flash | |||||||
| SHOWTIME FRENZY | CABINET FAN1 ABNORMAL | The Fan does not rotate properly. | Replace the fan | NO | YES | NONE | ? | Flash | |
| SHOWTIME FRENZY | CABINET FAN2 ABNORMAL | The Fan does not rotate properly. | Replace the fan | NO | YES | NONE | ? | Flash | |
| SHOWTIME FRENZY | POWER BOX FAN ABNORMAL | The Fan does not rotate properly. | Replace the fan | NO | YES | NONE | ? | Flash | |
| SHOWTIME FRENZY | PC TOWER FAN ABNORMAL | The Fan does not rotate properly. | Replace the fan | NO | YES | NONE | ? | Flash | |
| SHOWTIME FRENZY | TOP CABINET FAN1 ABNORMAL | The Fan does not rotate properly. | Replace the fan | NO | YES | NONE | ? | Flash | |
| SHOWTIME FRENZY | TOP CABINET FAN2 ABNORMAL | The Fan does not rotate properly. | Replace the fan | NO | YES | NONE | ? | Flash | |
| SHOWTIME FRENZY | TOP CABINET FAN3 ABNORMAL | The Fan does not rotate properly. | Replace the fan | NO | YES | NONE | ? | Flash | |
| SHOWTIME FRENZY | TOP CABINET FAN4 ABNORMAL | The Fan does not rotate properly. | Replace the fan | NO | YES | NONE | ? | Flash | |
| SHOWTIME FRENZY | CABINET FAN3 ABNORMAL | The Fan does not rotate properly. | Replace the fan | NO | YES | NONE | ? | Flash | |
| SHOWTIME FRENZY | CABINET FAN4 ABNORMAL | The Fan does not rotate properly. | Replace the fan | NO | YES | NONE | ? | Flash | |
| SHOWTIME FRENZY | POWER BOX A FAN ABNORMAL | The Fan does not rotate properly. | Replace the fan | NO | YES | NONE | ? | Flash | |
| SHOWTIME FRENZY | POWER BOX B FAN ABNORMAL | The Fan does not rotate properly. | Replace the fan | NO | YES | NONE | ? | Flash | |
| SHOWTIME FRENZY | POWER SUPPLY BOX THERMAL ERROR | Flash | |||||||
| SHOWTIME FRENZY | SIGNAGE POWER SUPPLY A THERMAL ERROR | Flash | |||||||
| SHOWTIME FRENZY | SIGNAGE POWER SUPPLY B THERMAL ERROR | Flash | |||||||
| SHOWTIME FRENZY | IO BOX COVER ACCESS DURING POWER DOWN | The target Door (Case, Cage) was opened while the power was turned OFF. | Reset key | YES | YES | NONE | ? | Flash | |
| SHOWTIME FRENZY | SPACER DRAIN DOOR OPEN ACCESS DURING POWER DOWN | The target Door (Case, Cage) was opened while the power was turned OFF. | Reset key | YES | YES | NONE | ? | Flash | |
| REEL ERRORS | REEL1 MOTOR ERROR | Flash | |||||||
| REEL ERRORS | REEL2 MOTOR ERROR | Flash | |||||||
| REEL ERRORS | REEL3 MOTOR ERROR | Flash | |||||||
| REEL ERRORS | REEL4 MOTOR ERROR | Flash | |||||||
| REEL ERRORS | REEL5 MOTOR ERROR | Flash | |||||||
| REEL ERRORS | REEL1 SENSOR ERROR | Flash | |||||||
| REEL ERRORS | REEL2 SENSOR ERROR | Flash | |||||||
| REEL ERRORS | REEL3 SENSOR ERROR | Flash | |||||||
| REEL ERRORS | REEL4 SENSOR ERROR | Flash | |||||||
| REEL ERRORS | REEL5 SENSOR ERROR | Flash | |||||||
| REEL ERRORS | REEL1 DETECTION ERROR | Flash | |||||||
| REEL ERRORS | REEL2 DETECTION ERROR | Flash | |||||||
| REEL ERRORS | REEL3 DETECTION ERROR | Flash | |||||||
| REEL ERRORS | REEL4 DETECTION ERROR | Flash | |||||||
| REEL ERRORS | REEL5 DETECTION ERROR | Flash | |||||||
| ONLINE COMMUNICATION ERRORS | COMMUNICATION DATA ERROR | Displayed when the progressive data is not correct. | AUTOMATIC | YES | NO | NONE | 20 | Flash | |
| ONLINE COMMUNICATION ERRORS | COMMUNICATION OFFLINE ERROR | Displayed when the communication with the SMIB is not proper. | Power off Check cables Power on | NO | YES | NONE | NA | Flash | |
| ONLINE COMMUNICATION ERRORS | HOST COMMUNICATION LINK DOWN | Displayed when communication with the SAS host is disconnected. | AUTOMATIC | YES | NO | NONE | Flash | ||
| ONLINE COMMUNICATION ERRORS | MACHINE DISABLE FROM HOST | Displayed when a MACHINE DISABLE command has been received from the SAS HOST. | AUTOMATIC | YES | NO | NONE | NA | Flash | |
| MECHANICAL METER ERRORS | MECHANICAL METER #1 FAULT/DISCONNECTED | The Mechanical meters are malfunctioning or disconnected. | Replace the Mechanical meter. | NO | YES | NONE | ? | Flash | |
| MECHANICAL METER ERRORS | MECHANICAL METER #2 FAULT/DISCONNECTED | The Mechanical meters are malfunctioning or disconnected. | Replace the Mechanical meter. | NO | YES | NONE | ? | Flash | |
| MECHANICAL METER ERRORS | MECHANICAL METER #3 FAULT/DISCONNECTED | The Mechanical meters are malfunctioning or disconnected. | Replace the Mechanical meter. | NO | YES | NONE | ? | Flash | |
| MECHANICAL METER ERRORS | MECHANICAL METER #4 FAULT/DISCONNECTED | The Mechanical meters are malfunctioning or disconnected. | Replace the Mechanical meter. | NO | YES | NONE | ? | Flash | |
| HOPPER ERRORS | EXTRA COINS PAID | Flash | |||||||
| HOPPER ERRORS | HOPPER RUNAWAY | Flash | |||||||
| HOPPER ERRORS | COIN OUT ERROR(HOPPER JAM) | Flash | |||||||
| HOPPER ERRORS | HOPPER TIMED OUT | Flash | |||||||
| HOPPER ERRORS | HOPPER DISCONNECTED | Flash | |||||||
| EXTENTION UNIT ERRORS | EXTEND MOTOR ERROR #1 | Flash | |||||||
| EXTENTION UNIT ERRORS | EXTEND MOTOR ERROR #2 | Flash | |||||||
| EXTENTION UNIT ERRORS | EXTEND MOTOR ERROR #3 | Flash | |||||||
| EXTENTION UNIT ERRORS | EXTEND MOTOR ERROR #4 | Flash | |||||||
| EXTENTION UNIT ERRORS | EXTEND MOTOR ERROR #5 | Flash | |||||||
| EXTENTION UNIT ERRORS | EXTEND MOTOR INDEX ERROR #1 | Flash | |||||||
| EXTENTION UNIT ERRORS | EXTEND MOTOR INDEX ERROR #2 | Flash | |||||||
| EXTENTION UNIT ERRORS | EXTEND MOTOR INDEX ERROR #3 | Flash | |||||||
| EXTENTION UNIT ERRORS | EXTEND MOTOR INDEX ERROR #4 | Flash | |||||||
| EXTENTION UNIT ERRORS | EXTEND MOTOR INDEX ERROR #5 | Flash | |||||||
| EXTENTION UNIT ERRORS | EXTEND MOTOR ENCODER ERROR #1 | Flash | |||||||
| EXTENTION UNIT ERRORS | EXTEND MOTOR ENCODER ERROR #2 | Flash | |||||||
| EXTENTION UNIT ERRORS | EXTEND MOTOR ENCODER ERROR #3 | Flash | |||||||
| EXTENTION UNIT ERRORS | EXTEND MOTOR ENCODER ERROR #4 | Flash | |||||||
| EXTENTION UNIT ERRORS | EXTEND MOTOR ENCODER ERROR #5 | Flash | |||||||
| DRAGON BONUS WHEEL | SERVER NETWORK ERROR | Communication between the Station and the Center Unit is disconnected. | RESET key. | NO | YES | NONE | ? | Flash | |
| DRAGON BONUS WHEEL | NOW CONNECTING... | Displayed while the main unit is connecting to the network. | AUTOMATIC | NO | YES | NONE | Flash | ||
| DRAGON BONUS WHEEL | CLIENT ID ERROR | It took too much time to restore the connection to the Casino Host. | Reboot the machine | YES | YES | NONE | ? | Flash | |
| DRAGON BONUS WHEEL | WAITING TO RECIEVE CONFIGURATIONS | Flash | |||||||
| DRAGON BONUS WHEEL | CONFIGURATIONS IS CHANGED. PLEASE POWER OFF-ON. | Flash | |||||||
| DRAGON BONUS WHEEL | BASE PROTOCOL VERSION IS UNMATHED | Flash | |||||||
| DRAGON BONUS WHEEL | GAME PROTOCOL VERSION IS UNMATHED | Flash | |||||||
| DRAGON BONUS WHEEL | GAME INTERRUPTED | Flash | |||||||
| DRAGON BONUS WHEEL | LIVE CAMERA DISCONNECTED | The Live Camera is not connected. | Check connection | YES | YES | NONE | ? | Flash | |
| DRAGON BONUS WHEEL | WARNING!! CONFIGURE MAIN UNIT ID | Flash | |||||||
| DRAGON BONUS WHEEL | WHEEL MOTOR ERROR | Flash | |||||||
| DRAGON BONUS WHEEL | WHEEL ORIGIN DETECT ERROR | Flash | |||||||
| DRAGON BONUS WHEEL | WHEEL POS1 SENSOR ERROR | Flash | |||||||
| DRAGON BONUS WHEEL | WHEEL POS2 SENSOR ERROR | Flash | |||||||
| DRAGON BONUS WHEEL | WHEEL POS INIT ERROR | Flash | |||||||
| DRAGON BONUS WHEEL | LIFTER BALL OUT SENSOR | Flash | |||||||
| DRAGON BONUS WHEEL | SHOOT BALL SET SENSOR ERROR | Flash | |||||||
| DRAGON BONUS WHEEL | SHOOT INIT SENSOR ERROR | Flash | |||||||
| DRAGON BONUS WHEEL | LIFTER WING ERROR | Flash | |||||||
| DRAGON BONUS WHEEL | LIFTER BALL CATCH ERROR | Flash | |||||||
| DRAGON BONUS WHEEL | BALL STOCK ERROR | Flash | |||||||
| DRAGON BONUS WHEEL | BALL EMPTY ERROR | Flash | |||||||
| DRAGON BONUS WHEEL | OUTER BALL FALL ERROR | Flash | |||||||
| DRAGON BONUS WHEEL | INNER BALL FALL ERROR | Flash | |||||||
| DRAGON BONUS WHEEL | OUTER BALL START ERROR | Flash | |||||||
| DRAGON BONUS WHEEL | INNER BALL START ERROR | Flash | |||||||
| DRAGON BONUS WHEEL | OUTER BALL COUNT ERROR | Flash | |||||||
| DRAGON BONUS WHEEL | INNER BALL COUNT ERROR | Flash | |||||||
| DRAGON BONUS WHEEL | OUTER POCKET SENSOR ERROR | Flash | |||||||
| DRAGON BONUS WHEEL | INNER POCKET SENSOR ERROR | Flash | |||||||
| DRAGON BONUS WHEEL | POCKET-GEAR ERROR | Flash | |||||||
| DRAGON BONUS WHEEL | OUTER BALL STOPPER ERROR | Flash | |||||||
| DRAGON BONUS WHEEL | INNER BALL STOPPER ERROR | Flash | |||||||
| DRAGON BONUS WHEEL | SOLENOID FOR OUTER GATE ERROR | Flash | |||||||
| DRAGON BONUS WHEEL | SOLENOID FOR INNER GATE ERROR | Flash | |||||||
| DRAGON BONUS WHEEL | ENCODER COUNT ERROR | Flash | |||||||
| DRAGON BONUS WHEEL | WHEEL CONTROLLER SECURITY CAGE OPEN | The target Door (Case, Cage) is open. | Close the door | YES | YES | NONE | ? | Flash | |
| DRAGON BONUS WHEEL | WHEEL CONTROLLER IO BOX COVER OPEN | The target Door (Case, Cage) is open. | Close the door | YES | YES | NONE | ? | Flash | |
| DRAGON BONUS WHEEL | WHEEL CONTROLLER PSU BOX FAN ABNORMAL | The Fan does not rotate properly. | Replace the fan | NO | YES | NONE | ? | Flash | |
| DRAGON BONUS WHEEL | WHEEL CONTROLLER PSU BOX THERMAL ERROR | Flash | |||||||
| DRAGON BONUS WHEEL | WHEEL CONTROLLER COMMUNICATION #6 ERROR (SIGA PCB) | No communication with the target PCB. | Replacing target PCB. | NO | YES | NONE | ? | Flash | |
| DRAGON BONUS WHEEL | WHEEL CONTROLLER COMMUNICATION #7 ERROR (SIGB PCB) | No communication with the target PCB. | Replacing target PCB. | NO | YES | NONE | ? | Flash | |
| DRAGON BONUS WHEEL | RECOVERY SET UP | Flash | |||||||
| DRAGON BONUS WHEEL | CENTER DEVICE ERROR | Flash | |||||||
| DRAGON BONUS WHEEL | WHEEL CONTROLLER TYPE MISMATCH | Flash | |||||||
| DRAGON BONUS WHEEL | WHEEL CONTROLLER DISCONNECTED | Flash | |||||||
| DRAGON BONUS WHEEL | LOW BACKUP BATTERY (BODY PCB) | Displayed when the battery for the BODY PCB is low. | Power off Replace a battery Power on | NO | YES | NONE | Flash | ||
| DRAGON BONUS WHEEL | CONSECUTIVE SAME RESULTS OF A WHEEL | Flash | |||||||
| DRAGON BONUS WHEEL | IO BOX COVER ACCESS DURING POWER DOWN | The target Door (Case, Cage) was opened while the power was turned OFF. | Reset key | YES | YES | NONE | ? | Flash | |
| DOOR EVENTS | MAIN DOOR ACCESS DURING POWER DOWN | Displayed when the door is accessed during power down. | Reset key | YES | YES | NONE | Flash | ||
| DOOR EVENTS | MAIN DOOR ACCESS DURING POWER DOWN | Displayed when the door is accessed during power down. | Reset key | YES | YES | NONE | Flash | ||
| DOOR EVENTS | MAIN DOOR ACCESS DURING POWER DOWN | Displayed when the door is accessed during power down. | Reset key | YES | YES | NONE | Flash | ||
| DOOR EVENTS | LOWER DOOR ACCESS DURING POWER DOWN | The target Door (Case, Cage) was opened while the power was turned OFF. | Reset key | YES | YES | NONE | ? | Flash | |
| DOOR EVENTS | MAIN DOOR ACCESS DURING POWER DOWN | Displayed when the door is accessed during power down. | Reset key | YES | YES | NONE | Flash | ||
| DOOR EVENTS | BILL DROP DOOR ACCESS DURING POWER DOWN | The target Door (Case, Cage) was opened while the power was turned OFF. | Reset key | YES | YES | NONE | ? | Flash | |
| DOOR EVENTS | BILL DROP DOOR ACCESS DURING POWER DOWN | The target Door (Case, Cage) was opened while the power was turned OFF. | Reset key | YES | YES | NONE | ? | Flash | |
| DOOR EVENTS | UNKNOWN DOOR ACCESS DURING POWER DOWN | The target Door (Case, Cage) was opened while the power was turned OFF. | Reset key | YES | YES | NONE | ? | Flash | |
| DOOR EVENTS | BILL DROP DOOR ACCESS DURING POWER DOWN | The target Door (Case, Cage) was opened while the power was turned OFF. | Reset key | YES | YES | NONE | ? | Flash | |
| DOOR EVENTS | UNKNOWN DOOR ACCESS DURING POWER DOWN | The target Door (Case, Cage) was opened while the power was turned OFF. | Reset key | YES | YES | NONE | ? | Flash | |
| DOOR EVENTS | UPPER DOOR ACCESS DURING POWER DOWN | The target Door (Case, Cage) was opened while the power was turned OFF. | Reset key | YES | YES | NONE | ? | Flash | |
| DOOR EVENTS | UPPER DOOR ACCESS DURING POWER DOWN | The target Door (Case, Cage) was opened while the power was turned OFF. | Reset key | YES | YES | NONE | ? | Flash | |
| DOOR EVENTS | SIDE SLIDE DOOR ACCESS DURING POWER DOWN | Displayed when the door is accessed during power down. | Reset key | YES | YES | NONE | Flash | ||
| DOOR EVENTS | UPPER DOOR ACCESS DURING POWER DOWN | The target Door (Case, Cage) was opened while the power was turned OFF. | Reset key | YES | YES | NONE | ? | Flash | |
| DOOR EVENTS | SIDE SLIDE DOOR ACCESS DURING POWER DOWN | Displayed when the door is accessed during power down. | Reset key | YES | YES | NONE | Flash | ||
| DOOR EVENTS | IO BOX COVER ACCESS DURING POWER DOWN | The target Door (Case, Cage) was opened while the power was turned OFF. | Reset key | YES | YES | NONE | ? | Flash | |
| DOOR EVENTS | IO BOX COVER ACCESS DURING POWER DOWN | The target Door (Case, Cage) was opened while the power was turned OFF. | Reset key | YES | YES | NONE | ? | Flash | |
| DOOR EVENTS | UNKNOWN DOOR ACCESS DURING POWER DOWN | The target Door (Case, Cage) was opened while the power was turned OFF. | Reset key | YES | YES | NONE | ? | Flash | |
| DOOR EVENTS | IO BOX COVER ACCESS DURING POWER DOWN | The target Door (Case, Cage) was opened while the power was turned OFF. | Reset key | YES | YES | NONE | ? | Flash | |
| DOOR EVENTS | UNKNOWN DOOR ACCESS DURING POWER DOWN | The target Door (Case, Cage) was opened while the power was turned OFF. | Reset key | YES | YES | NONE | ? | Flash | |
| DOOR EVENTS | SECURITY CAGE ACCESS DURING POWER DOWN | The target Door (Case, Cage) was opened while the power was turned OFF. | Reset key | YES | YES | NONE | ? | Flash | |
| DOOR EVENTS | SECURITY CAGE ACCESS DURING POWER DOWN | The target Door (Case, Cage) was opened while the power was turned OFF. | Reset key | YES | YES | NONE | ? | Flash | |
| DOOR EVENTS | SECURITY DOOR ACCESS DURING POWER DOWN | Displayed when the door is accessed during power down. | Reset key | YES | YES | NONE | Flash | ||
| DOOR EVENTS | SECURITY CAGE ACCESS DURING POWER DOWN | The target Door (Case, Cage) was opened while the power was turned OFF. | Reset key | YES | YES | NONE | ? | Flash | |
| DOOR EVENTS | SECURITY DOOR ACCESS DURING POWER DOWN | Displayed when the door is accessed during power down. | Reset key | YES | YES | NONE | Flash | ||
| DOOR EVENTS | RESERVE 92 | Flash | |||||||
| DOOR EVENTS | MEGA TOP COVER | Flash | |||||||
| DOOR EVENTS | MEGA TOP COVER DURING POWER DOWN | Flash | |||||||
| COIN ACCEPTOR ERRORS | COIN IN JAM | Flash | |||||||
| COIN ACCEPTOR ERRORS | REVERSE COIN IN | Flash | |||||||
| COIN ACCEPTOR ERRORS | COIN ACCEPTOR ERROR | Flash | |||||||
| COIN ACCEPTOR ERRORS | INAPPROPRIATE COIN IN | Flash | |||||||
| COIN ACCEPTOR ERRORS | DIVERTER ERROR | Flash | |||||||
| COIN ACCEPTOR ERRORS | COIN DROP JAM | Flash | |||||||
| BILL ACCEPTOR ERRORS / EVENTS | BILL STACKER JAM | Flash | |||||||
| BILL ACCEPTOR ERRORS / EVENTS | BILL ACCEPTOR JAM | Flash | |||||||
| BILL ACCEPTOR ERRORS / EVENTS | BILL STACKER REMOVED | Flash | |||||||
| BILL ACCEPTOR ERRORS / EVENTS | BILL STACKER FULL | Flash | |||||||
| BILL ACCEPTOR ERRORS / EVENTS | BILL ACCEPTOR COMMUNICATION ERROR | Flash | |||||||
| BILL ACCEPTOR ERRORS / EVENTS | BILL ACCEPTOR FAILURE | Flash | |||||||
| BILL ACCEPTOR ERRORS / EVENTS | BILL ACCEPTOR PAUSE | Flash | |||||||
| BILL ACCEPTOR ERRORS / EVENTS | BILL ACCEPTOR CHEAT | Flash | |||||||
| BILL ACCEPTOR ERRORS / EVENTS | EXCESSIVE BILL REJECTS | Flash | |||||||
| MESSAGE | COIN OUT | Flash | |||||||
| COIN ERRORS | COIN ACCEPTOR ERROR | Flash | |||||||
| MECHANICAL METER ERRORS | MECHANICAL METER #5 FAULT/DISCONNECTED | The Mechanical meters are malfunctioning or disconnected. | Replace the Mechanical meter. | NO | YES | NONE | ? | Flash | |
| MECHANICAL METER ERRORS | MECHANICAL METER #6 FAULT/DISCONNECTED | The Mechanical meters are malfunctioning or disconnected. | Replace the Mechanical meter. | NO | YES | NONE | ? | Flash | |
| MECHANICAL METER ERRORS | MECHANICAL METER #7 FAULT/DISCONNECTED | The Mechanical meters are malfunctioning or disconnected. | Replace the Mechanical meter. | NO | YES | NONE | ? | Flash | |
| MECHANICAL METER ERRORS | MECHANICAL METER #8 FAULT/DISCONNECTED | The Mechanical meters are malfunctioning or disconnected. | Replace the Mechanical meter. | NO | YES | NONE | ? | Flash | |
| SYSTEM ERRORS | LOW BACKUP BATTERY (NVRAM) | The remaining battery of the target PCB is lower than a specified level. | Replace the battery. | NO | YES | NONE | ? | Flash | |
| SYSTEM ERRORS | MEDIA REMOVED DURING POWER DOWN | Flash | |||||||
| SYSTEM ERRORS | IDE CABLE DISCONNECTED DURING POWER DOWN | Flash | |||||||
| SYSTEM ERRORS | POWER OFF DURING SETTING | Displayed when the power is turned off during the setting is being updated. | RESET key. | NO | YES | NONE | 20 | Flash | |
| MESSAGE | PLEASE TAKE THE TICKET OR RECEIPT | A printed ticket or receipt was not collected. | Take the ticket or receipt | YES | NO | NONE | ? | Flash | |
| MESSAGE | PRINTING NOW ... | Flash | |||||||
| MESSAGE | PLEASE WAIT, TICKET BEING PREPARED | Flash | |||||||
| MESSAGE | VALIDATION ID NOT CONFIGURED | LP4C is not sent from the Casino Host. | Check if the current Casino Host supports SECURE ENHANCED VALIDATION. | YES | YES | NONE | ? | Flash | |
| SYSTEM RELATED MESSAGES | TICKET PRINTING ERROR | Power was turned OFF during ticket printing. | RESET key. | NO | YES | NONE | ? | Flash | |
| SYSTEM RELATED MESSAGES | TICKET HISTORY BUFFER FULL | The Print ticket information reached its maximum capacity. | AUTOMATIC | Flash | |||||
| SYSTEM RELATED MESSAGES | SELF AUDIT ERROR | Displayed when the AUDIT data is broken. | Power off Power on RAM Clear | NO | YES | YES, RAM must be cleared | NA | Flash | |
| SYSTEM RELATED MESSAGES | PCB READ ERROR | Flash | |||||||
| SYSTEM RELATED MESSAGES | CPU FAN ABNORMAL | Displayed when the Fan does not rotate properly. | Power off Replace a fan Power on | NO | YES | NONE | Flash | ||
| SYSTEM RELATED MESSAGES | SECURITY CAGE FAN ABNORMAL | The Fan does not rotate properly. | Replace the fan | NO | YES | NONE | ? | Flash | |
| SYSTEM RELATED MESSAGES | SECURITY CAGE FAN ABNORMAL | The Fan does not rotate properly. | Replace the fan | NO | YES | NONE | ? | Flash | |
| SYSTEM RELATED MESSAGES | SECURITY BOX FAN ABNORMAL | The Fan does not rotate properly. | Replace the fan | NO | YES | NONE | ? | Flash | |
| SYSTEM RELATED MESSAGES | SECURITY CAGE FAN ABNORMAL | The Fan does not rotate properly. | Replace the fan | NO | YES | NONE | ? | Flash | |
| SYSTEM RELATED MESSAGES | SECURITY BOX FAN ABNORMAL | The Fan does not rotate properly. | Replace the fan | NO | YES | NONE | ? | Flash | |
| SYSTEM RELATED MESSAGES | CAN NOT OPEN EEPROM | Flash | |||||||
| SYSTEM RELATED MESSAGES | CAN NOT OPEN GAME SELECT CHIP | Flash | |||||||
| SYSTEM RELATED MESSAGES | BODY PCB CHANGED | Displayed when the BODY PCB is replaced. | Reset key | NO | YES | NONE | Flash | ||
| SYSTEM RELATED MESSAGES | DOOR PCB CHANGED | The target PCB was replaced. | RESET key. | NO | YES | NONE | ? | Flash | |
| SYSTEM RELATED MESSAGES | BODY PCB SRAM ERROR | Flash | |||||||
| SYSTEM RELATED MESSAGES | DOOR PCB SRAM ERROR | Flash | |||||||
| SYSTEM RELATED MESSAGES | POWER UP - SAVE | No | Not flash | ||||||
| SYSTEM RELATED MESSAGES | ALL DOOR CLOSED | Displayed when all doors are closed. | AUTOMATIC (with playing the game) | NO | NO | NONE | NA | No | Not flash |
| SYSTEM RELATED MESSAGES | VOID PRINTED TICKET AND REPRINT | Flash | |||||||
| SYSTEM RELATED MESSAGES | REPRINT TICKET | Flash | |||||||
| SYSTEM RELATED MESSAGES | LINK PROGRESSIVE COMMUNICATION FAILURE | Flash | |||||||
| SYSTEM RELATED MESSAGES | RAM ERROR | Displayed when RAM cannot be read. | Power off Power on RAM Clear | NO | YES | RAM must be cleared to clear this error. | 20 | Flash | |
| SYSTEM RELATED MESSAGES | PROGRAM CORRUPTED | Displayed when the program loaded on the RAM corrupted. | Power off Replace a Compact Flash Power on Reset key | NO | YES | NONE. | 20 | Flash | |
| SYSTEM RELATED MESSAGES | Bill not accepted if Credits over $50000 are registered | Flash | |||||||
| SYSTEM RELATED MESSAGES | MEDIA CORRUPTED | Displayed when the MEDIA is incorrect. | Power off Replace a MEDIA Power on RAM Clear | NO | YES | NONE, RAM must be cleared | NA | Flash | |
| SYSTEM RELATED MESSAGES | FIRM CORRUPTED | Displayed when the FIRM is incorrect. | Power off Replace a FIRM Power on RAM Clear | NO | YES | NONE, RAM must be cleared | NA | Flash | |
| SYSTEM RELATED MESSAGES | CONFIGURATION SETTING IS CLEARED. | It is impossible to read the Configuration settings, or they were deleted. | 1. RESET key 2. Reboot the machine to activate the settings. 3. Perform RAM clear [Setting USB dongle required]. Perform the Configuration again. | NO | YES | NONE, RAM must be cleared | NA | Flash | |
| SYSTEM RELATED MESSAGES | SET THE CONFIGURATION AGAIN. | It is impossible to read the Configuration settings, or they were deleted. | 1. RESET key 2. Reboot the machine to activate the settings. 3. Perform RAM clear [Setting USB dongle required]. Perform the Configuration again. | NO | YES | NONE, RAM must be cleared | NA | Flash | |
| SYSTEM RELATED MESSAGES | TOUCH SCREEN DISCONNECTED | It is not possible to connect to the touch screen. | Check the connection | YES | YES | NONE | ? | Flash | |
| SYSTEM RELATED MESSAGES | 2ND TOUCH SCREEN DISCONNECTED | It is not possible to connect to the touch screen. | Check the connection | YES | YES | NONE | ? | Flash | |
| SYSTEM RELATED MESSAGES | NOT TOUCH SCREEN ID | The touch screen ID is not correctly configured. | Check connection | YES | YES | NONE | ? | Flash | |
| SYSTEM RELATED MESSAGES | NOW VALIDATION IS CHECKING | Flash | |||||||
| SYSTEM RELATED MESSAGES | MEDIA VERSION TYPE UNMATCHED | Flash | |||||||
| SYSTEM RELATED MESSAGES | LINK CONTROLLER IS POWER UP | Flash | |||||||
| SYSTEM RELATED MESSAGES | LINK CONTROLLER MALFUNCTION | Flash | |||||||
| SYSTEM RELATED MESSAGES | LINK CONTROLLER DOOR OPEN | Flash | |||||||
| SYSTEM RELATED MESSAGES | LINK CONTROLLER MAINTENANCE | Flash | |||||||
| SYSTEM RELATED MESSAGES | RESIDUAL CREDITS CANNOT BE PAID OUT | Flash | |||||||
| SYSTEM RELATED MESSAGES | CLIENT ID SHOULD BE UNIQUE.SET CLIENT ID AGAIN. | Flash | |||||||
| SYSTEM RELATED MESSAGES | DOWNLOAD FILE IS MISMATCH | Flash | |||||||
| SYSTEM RELATED MESSAGES | COMMUNICATION #4 ERROR (SUB PCB) | Flash | |||||||
| SYSTEM RELATED MESSAGES | RESERVE 17 | Flash | |||||||
| SYSTEM RELATED MESSAGES | CURRENCY IS MISMATCH(LINK PROGRESSIVE) | Flash | |||||||
| SYSTEM RELATED MESSAGES | BASE CREDIT IS MISMATCH(LINK PROGRESSIVE) | Flash | |||||||
| SYSTEM RELATED MESSAGES | RESERVE 20 | Flash | |||||||
| SYSTEM RELATED MESSAGES | SOUND INITIALIZATION ERROR | Flash | |||||||
| SYSTEM RELATED MESSAGES | COMMUNICATION #10 ERROR (SUB IO 00) | Flash | |||||||
| SYSTEM RELATED MESSAGES | COMMUNICATION #11 ERROR (SUB IO 01) | Flash | |||||||
| SYSTEM RELATED MESSAGES | COMMUNICATION #12 ERROR (SUB IO 02) | Flash | |||||||
| SYSTEM RELATED MESSAGES | COMMUNICATION #13 ERROR (SUB IO 03) | Flash | |||||||
| SYSTEM RELATED MESSAGES | COMMUNICATION #14 ERROR (SUB IO 04) | Flash | |||||||
| SYSTEM RELATED MESSAGES | COMMUNICATION #15 ERROR (SUB IO 05) | Flash | |||||||
| SYSTEM RELATED MESSAGES | COMMUNICATION #16 ERROR (SUB IO 06) | Flash | |||||||
| SYSTEM RELATED MESSAGES | COMMUNICATION #17 ERROR (SUB IO 07) | Flash | |||||||
| SYSTEM RELATED MESSAGES | COMMUNICATION #18 ERROR (SUB IO 08) | Flash | |||||||
| SYSTEM RELATED MESSAGES | COMMUNICATION #19 ERROR (SUB IO 09) | Flash | |||||||
| SYSTEM RELATED MESSAGES | COMMUNICATION #20 ERROR (SUB IO 10) | Flash | |||||||
| SYSTEM RELATED MESSAGES | COMMUNICATION #21 ERROR (SUB IO 11) | Flash | |||||||
| SYSTEM RELATED MESSAGES | COMMUNICATION #22 ERROR (SUB IO 12) | Flash | |||||||
| SYSTEM RELATED MESSAGES | COMMUNICATION #23 ERROR (SUB IO 13) | Flash | |||||||
| SYSTEM RELATED MESSAGES | COMMUNICATION #24 ERROR (SUB IO 14) | Flash | |||||||
| SYSTEM RELATED MESSAGES | COMMUNICATION #25 ERROR (SUB IO 15) | Flash | |||||||
| SYSTEM RELATED MESSAGES | NOKI PCB CHANGED | Displayed when the NOKI PCB is replaced. | Reset key | NO | YES | NONE | Flash | ||
| SYSTEM RELATED MESSAGES | NOKI PCB SRAM ERROR | Flash | |||||||
| SYSTEM RELATED MESSAGES | XCOM PCB CHANGED | The target PCB was replaced. | RESET key. | NO | YES | NONE | ? | Flash | |
| SYSTEM RELATED MESSAGES | XCOM PCB SRAM ERROR | Flash | |||||||
| SYSTEM RELATED MESSAGES | SIGA PCB CHANGED | The target PCB was replaced. | RESET key. | NO | YES | NONE | ? | Flash | |
| SYSTEM RELATED MESSAGES | SIGA PCB SRAM ERROR | Flash | |||||||
| SYSTEM RELATED MESSAGES | SIGB PCB CHANGED | The target PCB was replaced. | RESET key. | NO | YES | NONE | ? | Flash | |
| SYSTEM RELATED MESSAGES | SIGB PCB SRAM ERROR | Flash | |||||||
| SYSTEM RELATED MESSAGES | SIGC PCB CHANGED | The target PCB was replaced. | RESET key. | NO | YES | NONE | ? | Flash | |
| SYSTEM RELATED MESSAGES | SIGC PCB SRAM ERROR | Flash | |||||||
| SYSTEM RELATED MESSAGES | SIGD PCB CHANGED | The target PCB was replaced. | RESET key. | NO | YES | NONE | ? | Flash | |
| SYSTEM RELATED MESSAGES | SIGD PCB SRAM ERROR | Flash | |||||||
| SYSTEM RELATED MESSAGES | GAME USB DONGLE FAULT | It is not possible to read the GAME USB Dongle. | Replace the GAME USB Dongle | NO | YES | NONE | ? | Flash | |
| SYSTEM RELATED MESSAGES | EXCEPTION BUFFER OVERFLOW | Displayed when event buffer of transaction to the host is full. | AUTOMATIC | NO | YES | NONE | NA | Flash | |
| SYSTEM RELATED MESSAGES | EVENT BUFFER CORRUPT | Displayed when event buffer of transaction to the host is corrupted. | Wait a command from the host | NO | YES | NONE | NA | Flash | |
| SYSTEM RELATED MESSAGES | NOT YET CONNECTED TO HOST(LINK PROGRESSIVE) | Flash | |||||||
| SYSTEM RELATED MESSAGES | DISCONNECT TO HOST(LINK PROGRESSIVE) | Flash | |||||||
| SYSTEM RELATED MESSAGES | MALFUNCTION: REBOOT THE MACHINE | Flash | |||||||
| SYSTEM RELATED MESSAGES | MALFUNCTION: PERFORM RAM CLEAR | Flash | |||||||
| SYSTEM RELATED MESSAGES | G2S COMMUNICATION OFFLINE ERROR | Flash | |||||||
| SYSTEM RELATED MESSAGES | G2S COMMUNICAITON PREPARING | Flash | |||||||
| SYSTEM RELATED MESSAGES | G2S QUEUE OVERFLOW | Flash | |||||||
| SYSTEM RELATED MESSAGES | WRITING CARD | Flash | |||||||
| SYSTEM RELATED MESSAGES | FINISHED, WROTE CARD | Flash | |||||||
| SYSTEM RELATED MESSAGES | USED CARD - SAME MACHINE | Flash | |||||||
| SYSTEM RELATED MESSAGES | USED CARD - OTHER MACHINE | Flash | |||||||
| SYSTEM RELATED MESSAGES | NOT SUPPORT CARD TYPE | Flash | |||||||
| SYSTEM RELATED MESSAGES | FAILED WRITE | Flash | |||||||
| SYSTEM RELATED MESSAGES | NO SERVICE FOR CARD | Flash | |||||||
| SYSTEM RELATED MESSAGES | GENERAL CARD ERROR | Flash | |||||||
| SYSTEM RELATED MESSAGES | PCB CHANGED | The target PCB was replaced. | RESET key. | NO | YES | NONE | ? | Flash | |
| SYSTEM RELATED MESSAGES | RAM RECOVERY REQUIRED: TURN THE RESET KEY | Flash | |||||||
| SYSTEM RELATED MESSAGES | 4TH MONITOR COMMUNICATION OFFLINE ERROR | Flash | |||||||
| SYSTEM RELATED MESSAGES | RESEND TICKET INSERTED EXCEPTION | Flash | |||||||
| SYSTEM RELATED MESSAGES | CONFIGURATION MISMATCH. | Flash | |||||||
| SYSTEM RELATED MESSAGES | SET THE CONFIGURATION AGAIN. | Flash | |||||||
| SYSTEM RELATED MESSAGES | THRESHOLD AMOUNT EXCEEDED | Flash | |||||||
| SYSTEM RELATED MESSAGES | CALL ATTENDANT | Flash | |||||||
| SYSTEM RELATED MESSAGES | CASHOUT TO HOST FAILURE | Flash | |||||||
| SYSTEM RELATED MESSAGES | MEDIA REMOVED. | Flash | |||||||
| SYSTEM RELATED MESSAGES | TURN OFF AND ON THE MACHINE | Flash | |||||||
| SYSTEM RELATED MESSAGES | BILL STACKER INSERTED | Flash | |||||||
| SYSTEM RELATED MESSAGES | CONTROL PANEL DATA DOWNLOAD FAILURE | Flash | |||||||
| SYSTEM RELATED MESSAGES | CHECK CONNECTION AND DOWNLOAD AGAIN. | Flash | |||||||
| SYSTEM RELATED MESSAGES | TIME CLOCK MISMATCHED | Flash | |||||||
| SYSTEM RELATED MESSAGES | NO VIDEO CARD ERROR | Flash | |||||||
| SYSTEM RELATED MESSAGES | TICKET PRINTER PAPER NOT SET CORRECTLY | Flash | |||||||
| SYSTEM RELATED MESSAGES | DISCONNECT TO HOST(INTERNAL LINK) | Flash | |||||||
| SYSTEM RELATED MESSAGES | CURRENCY IS MISMATCH(INTERNAL LINK) | Flash | |||||||
| SYSTEM RELATED MESSAGES | BASE CREDIT IS MISMATCH(INTERNAL LINK) | Flash | |||||||
| SYSTEM RELATED MESSAGES | PRIMARY PORT OFFLINE ERROR | Flash |